Detail Data Acquisition System MS5D, MS5
Data acquisition system MS5D, MS5
The complete solution for monitoring of temperature, humidity and other values especially in following applications:
* Food and beverages industry (HACCP)
* Pharmaceutical industry (GMP)
* Blood stations, pharmacies
* Horticulture and cultivation of plants
* HVAC (heating, ventilation, air conditioning, cooling
* Building and energy management
* Building automation
* Research and development
* Laboratories (GLP)
Single-channel to sixteen-channel data loggers are designed for recording of values from transducers of variety of quantities, alarm state indication, and process control. Data logger with transducers configured accordingly to client order can measure analog signals, frequency, count impulses, evaluate two-state quantities and read data from devices compatible with Modbus RTU and ADAM Advantech protocol. Input signals are connected to removable terminal block located on the logger upper side. Analyzing of the record is enabled after data download to the personal computer by means of the included program via USB, RS232, Ethernet or GSM modem. Local or remote online data presentation is also enabled.
New generation data acquisition system especially enables:
* online data acquisition by means of the Ethernet interface. Communication via: SNMP, SOAP, internet www pages
* to get information from data logger by means of the SMS messages - actual values, alarms, memory occupation and others - as response to SMS request from the user and after alarm creation at the logger. Data logger should be connected via GSM modem supporting SMS.
* to configure individually each input channel for measurement, alarm evaluation and data logging, including individual data logging interval for each input.
* each input channel can be individually programmed for different modes of record (continuous record, time dependent record, record only if specified logic conditions are matched, record triggered by external signal, etc.). It is enabled to record with shorter interval in case, measured values match previously defined conditions e.g. to map in detail trouble state. It is also enabled to memorize actual value and time if defined time event appears.
* to set up to four different logic conditions for each channel to active alarm. Each condition compares measured values from inputs with set limits. It is possible to set hysteresis and delay of condition validity.
* to assign to each input channel name of actual recorded process to identify monitored object (e.g. type of monitored product). It is enabled to select this name from data logger keyboard during the operation.
* to indicate alarm state after matching defined combination up to four alarms from any inputs.
* to store several configuration profiles (all logger parameters setting) for different measuring tasks and select profiles from logger keyboard.
* Input signals are connected by means of the removeable terminal connector. Each input channel has three terminals - including shielding.
Following data loggers are available:
data logger - larger photo
MS5D
* fully equipped data logger
* dual line alphanumerical LCD display
* four control buttons
* 32 alarm LEDs
data logger - larger photo
MS5
* all functions as MS5D
* without LCD display, without control buttons, without alarm LEDs
* alarm is indicated by one common LED.
TECHNICAL PARAMETERS OF DATA LOGGER
Memory type: internal SRAM, backed-up by Lithium battery
Total memory capacity: 2MB (up to 480 000 values)
Data logging mode: noncyclic - logging stops after filling the memory
cyclic - after filling memory oldest data is overwritten by new
Data logging interval: adjustable individually for all input channels from 1 second to 24 hours
Real time clock: year, leap year, month, day, hour, minute, second, backed-up by Lithium battery
Input measured values (1 to 16 inputs): are defined for each channel by installed input modules (see table) accordingly to user requirements
Resolution of the AD converter (analog channels): 16 bits, conversion duration approximately 60ms/channel
Supported interface for communication with computer:
* RS232 (RxD,TxD,RTS,CTS,GND), cable up to 15 m - included. Enables direct connection with the PC or via line modem or GSM modem.
* USB interface - included
* RS485 - cable up to 1200 m, galvanically isolated, possibility of connection of several data loggers to one communication link - included
* Ethernet interface LAN - optional. Online communication via: SNMP, SOAP, internet www pages
Communication speed: 9600, 19200, 57600, 115200 Bd
Outputs for alarm indication: 1) Red LED at the side of the case, 32 LEDs - only MS5D data logger
2) Relay max. 8A/250Vac, switching-over contact
3) Voltage signal 0V/4.8V, maximum current 50mA, output designed for connection of external audio indication unit or telephone voice dialer
4) Alarm can be signalled also by e-mail message, SNMP trap, SMS - please see optional accessory
Power: 9 to 30Vdc, 24Vdc recommended
Operating temperature range: 0 to +50°C
Dimensions including connectors: 215 x 225 x 60 mm
Protection: IP20
Warranty: 2 years
Communication interfaces:
communication interfaces
TYPES OF LOGGER INPUTS
Numb. Type Measured value Accuracy Note
M1001 A0 dc current 4 to 20 mA ±0.1% FS With source approximately 21V for two-wire transducers with current loop (e.g. temperature and humidity transducers Comet). Only galvanic not isolated.
M1002 A1* dc current 4 to 20 mA ±0.1% FS for passive sensing of current
M1003 B0* dc current 0 to 20mA ±0.1% FS
M1004 B1* dc current 0 to 1A ±0.1% FS
M1005 B2* dc current 0 to 5A ±0.1% FS
M1006 C0 ac current 0 to 20mA ±1% FS galvanic isolated
M1007 C1 ac current 0 to 1A ±1% FS galvanic isolated
M1008 C2 ac current 0 to 5A ±1% FS galvanic isolated
M1009 D0* dc voltage 0 to 100mV ±0.1% FS
M1010 D1* dc voltage 0 to 1V ±0.1% FS
M1011 D2* dc voltage 0 to 10V ±0.1% FS
M1056 D5* dc voltage -10V to +10V ±0,1% FS
(± 20 mV) New !
M1055 D4* dc voltage 0 to 75V ±0.1% FS New !
M1013 E0 ac voltage 0 to 100mV ±1% FS galvanic isolated
M1014 E1 ac voltage 0 to 1V ±1% FS galvanic isolated
M1015 E2 ac voltage 0 to 10V ±1% FS galvanic isolated
M1059 E4 ac voltage 0 to 50V ±1% FS New !
galvanically isolated
M1017 F* measurement of resistance (specify the range) ±0.1% FS two-wire connection
M1018 J* input for Nickel RTD temperature sensor Ni1000, 6180 ppm/°C, range -50 to +250°C -50 to 100°C ±0.2°C 100 to 250°C ±0.2% from reading
M1019 K* input for Platinum RTD temperature sensor Pt100, range -140 to +600°C -140 to+100°C ±0.2°C 100 to 600°C ±0.2% from reading two-wire connection
M1020 K1* input for Platinum RTD temperature sensor Pt1000, range -140 to +600°C -140 to+100°C ±0.2°C 100 to 600°C ±0.2% from reading two-wire connection
M1060 K3 precise input for Platinum RTD temperature sensor Pt1000
range -10 to +50°C ±0.06°C New !
Two-wire connection.
Only galvanically not isolated.
M1021 N* thermocouple K (NiCr-Ni) range -70 to +1300°C ±0.3% from reading + 1.5°C linearized, cold junction compensation
M1054 T* thermocouple T (Cu-CuNi) range -200 to +400°C ±0.3% from reading + 1.5°C linearized, cold junction compensation
M1022 O* thermocouple J (Fe-Co) range -200 to 750°C ±0.3% from reading + 1.5°C linearized, cold junction compensation
M1023 P* thermocouple S (Pt10%Rh-Pt), range 0 to 1700°C ±0.3% from reading + 1.5°C from +200 to +1700°C linearized, cold junction compensation
M1024 Q* thermocouple B (Pt30%Rh-Pt), range +100 to +1800°C ±0.3% from reading + 1.0°C from +300 to +1800°C linearized, without cold junction compensation
M1041 S* binary input for potential-less contacts maximum resistance of closed contact: 1000 ohms minimum duration for recording: 200ms
M1042 S1 binary voltage input voltage for "switched ON" state: 3 to 30Vdc, input current in the"switched ON" state: 1 to 9mA-depending on the applied voltage, minimum duration for indication of change: 200ms, galvanic isolated
M1044 CTU counter input for voltage signal voltage for "HIGH" state (for counter status change): 3 to 24Vdc maximum pulse frequency 5kHz, backed-up operation, galvanic isolated
M1045 CTK counter input for potential-less contacts and open collector maximum pulse frequency 5kHz, programmable filter of pulse ringing, backed-up operation during power mains failure, maximum resistance of closed contact: 10 kohms minimum resistance of open contact: 250 kohms, galvanic unisolated
M1047 FU input for measurement of frequency of voltage signal 0 to 5kHz, resolution 1Hz, accuracy ±(0.2% from reading + 1Hz) input voltage for state "H": 3 to 24Vdc input current in state "H": approximately 7mA minimum duration of input impuls: 30us, galvanic isolated
M1048 FK input for measurement of frequency of contact switching 0 to 5kHz, resolution 1Hz, accuracy ±(0.2% from reading + 1Hz) maximum resistance of closed contact: 10 kohms minimum resistance of open contact: 250 kohms, minimum duration of input pulse: 30us, galvanic unisolated
M1061 RP input for serial signal RS485 for devices supporting Modbus RTU or Advantech protocol E.g. measurement from Comet Tx41x temperature, humidity, pressure, transmitters.
Only devices using same communication protocol and same communication speed can be connected to one RP module.
Several RP modules can be installed in MS5 data logger.
More information is in Manual Appendixes. Maximum speed 115200Bd.
Galvanic isolated.
Not compatible with older models MS234+.
Input module for monitoring system
Input module A0 4-20mA
Input module for monitoring system
Counter input module CTU
Larger photo of monitoring system
View of power and communication connectors
Larger photo of monitoring system
View of power and input connectors
- three terminals/input
Notes: Inputs marked ( * ) are not galvanic isolated and have common ground. These inputs are available also as galvanic isolated. Galvanic isolated analog inputs are marked with letter G following the name of input type (e.g. input for passive measurement of current 4-20mA - type A1 - with galvanic isolation is marked A1G). Galvanic isolation is not designed as safety protection.
Accessories
Data Sheet in pdfData Sheet in pdf
Basic Manual in pdfBasic Manual in pdf
Manual in pdfManual Appendixes in pdf
Declaration of conformity in pdf formatDeclaration of conformity in pdf format
Configuration and Ordering Form
Electronic form for easy selection of required monitoring system and accessories.
Send us please your filled Form as an e-mail attachment.
Run Configuration and Ordering Form
Tampilkan Lebih Banyak